TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Ambient Air Temperature For Storage:
- -50-85°C
- Maximum Operating Rate:
- 25 cyc/h
- Warranty:
- 18 months
- Fire Resistance:
- 960°C IEC 60695-2-11
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1
- Operating Altitude:
- 5000 m
- Device Application:
- motor protection
- Mechanical Durability:
- 40000 cycles
- Electrical Durability:
- 10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
- Motor Power Kw:
- 37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
- Climatic Withstand:
- IACS E10
- Power Dissipation Per Pole:
- 4.6 W
- Range Of Product:
- TeSys GV4
- Color:
- Gray RAL 7016)
- Pollution Degree:
- 3
- Rated Duty:
- continuous IEC 60947-4-1
- Environmental Disclosure:
- ENVPEP1704004EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Magnetic Tripping Current:
- 1955-1955 A
- Ik Degree Of Protection:
- IK07 IEC 62262
- Mercury Free:
- Yes
- Trip Unit Technology:
- electronic || thermal-magnetic
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ith] Conventional Free Air Thermal Current:
- 115 A IEC 60947-4-1
- Ambient Air Temperature For Operation:
- -25-70°C
- Device Short Name:
- GV4PE
- Width:
- 81 mm
- Circularity Profile:
- ENVEOLI1704004EN
- Product Name:
- TeSys GV4 || TeSys Deca
- Tightening Torque:
- 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
- Suitability For Isolation:
- yes IEC 60947-1
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Weight:
- 1.45 kg
- Connections - Terminals:
- EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
- Control Type:
- toggle
- [Ui] Rated Insulation Voltage:
- 800 V AC 50/60 Hz IEC 60947-2
- Country of Origin:
- Poland
- Eu Rohs Directive:
- Compliant with Exemptions
- Depth:
- 116 mm
- Ip Degree Of Protection:
- IP40 IEC 60529
- Mechanical Robustness:
- vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
- Product Or Component Type:
- motor circuit breaker
- Sustainable Offer Status:
- Green Premium product
- Operating Position:
- any position
- Standards:
- CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
- Range:
- TeSys Deca
- Rohs Exemption Information:
- Yes
- Poles Description:
- 3P