Schneider Electric

Schneider Electric GV4PE115S6 Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PE115S6
MPN:
GV4PE115S6
Condition:
New
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Eu Rohs Directive:
Compliant with Exemptions
Phase Failure Sensitivity:
yes IEC 60947-4-1
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
116 mm
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Halogen Content Performance:
Halogen free plastic parts product
Range:
TeSys Deca
Connections - Terminals:
lugs-ring terminals
Product Name:
TeSys GV4 || TeSys Deca
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Operating Altitude:
5000 m
Line Rated Current:
115 A
Width:
81 mm
Net Weight:
1.45 kg
Rated Duty:
continuous IEC 60947-4-1
Operating Position:
any position
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1704004EN
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Control Type:
toggle
Climatic Withstand:
IACS E10
Trip Unit Technology:
thermal-magnetic || electronic
Ik Degree Of Protection:
IK07 IEC 62262
Maximum Operating Rate:
25 cyc/h
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Product Or Component Type:
motor circuit breaker
Color:
Gray RAL 7016)
Magnetic Tripping Current:
1955-1955 A
Weight:
1.45 kg
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Height:
155 mm
Poles Description:
3P
Suitability For Isolation:
yes IEC 60947-1
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Power Dissipation Per Pole:
4.6 W
Mechanical Durability:
40000 cycles
Range Of Product:
TeSys GV4
Fire Resistance:
960°C IEC 60695-2-11
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile:
ENVEOLI1704004EN
Ip Degree Of Protection:
IP40 IEC 60529
$1,492.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose