Schneider Electric

Schneider Electric GV4PE80S6 Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 100kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PE80S6
MPN:
GV4PE80S6
Condition:
New
Fire Resistance:
960°C IEC 60695-2-11
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 30-30 kW 500 V AC 50/60 Hz || 37-37 kW 660...690 V AC 50/60 Hz || 45-45 kW 660...690 V AC 50/60 Hz || 55-55 kW 660...690 V AC 50/60 Hz || 30-30 kW 4
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Range Of Product:
TeSys GV4
Depth:
116 mm
Environmental Disclosure:
ENVPEP1704004EN
Line Rated Current:
80 A
Ambient Air Temperature For Storage:
-50-85°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Operating Position:
any position
Poles Description:
3P
Device Application:
motor protection
Range:
TeSys Deca
Ip Degree Of Protection:
IP40 IEC 60529
Circularity Profile:
ENVEOLI1704004EN
Mechanical Durability:
40000 cycles
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Warranty:
18 months
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Ambient Air Temperature For Operation:
-25-70°C
Climatic Withstand:
IACS E10
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Weight:
1.45 kg
Eu Rohs Directive:
Compliant with Exemptions
Country of Origin:
Poland
Phase Failure Sensitivity:
yes IEC 60947-4-1
Maximum Operating Rate:
25 cyc/h
Suitability For Isolation:
yes IEC 60947-1
Control Type:
toggle
Trip Unit Technology:
electronic || thermal-magnetic
Ik Degree Of Protection:
IK07 IEC 62262
Rated Duty:
continuous IEC 60947-4-1
Mercury Free:
Yes
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Product Or Component Type:
motor circuit breaker
Connections - Terminals:
lugs-ring terminals
Device Short Name:
GV4PE
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Halogen Content Performance:
Halogen free plastic parts product
Pollution Degree:
3
Operating Altitude:
5000 m
Power Dissipation Per Pole:
4.6 W
$1,492.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).