Schneider Electric

Schneider Electric GV4PEM115N Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic multifunction, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PEM115N
MPN:
GV4PEM115N
Condition:
New
Ik Degree Of Protection:
IK07 IEC 62262
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Operating Position:
any position
Control Type:
toggle
Device Short Name:
GV4PEM
Circularity Profile:
ENVEOLI1704004EN
Power Dissipation Per Pole:
4.6 W
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Warranty:
18 months
Ip Degree Of Protection:
IP40 IEC 60529
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Halogen Content Performance:
Halogen free plastic parts product
Line Rated Current:
115 A
Climatic Withstand:
IACS E10
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Width:
81 mm
Range Of Product:
TeSys GV4
Mechanical Durability:
40000 cycles
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Maximum Operating Rate:
25 cyc/h
Environmental Disclosure:
ENVPEP1704004EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Rated Duty:
continuous IEC 60947-4-1
Mercury Free:
Yes
Range:
TeSys Deca
Product Or Component Type:
motor circuit breaker
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Product Name:
TeSys GV4 || TeSys Deca
Depth:
116 mm
Country of Origin:
Poland
Poles Description:
3P
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Operating Altitude:
5000 m
Rohs Exemption Information:
Yes
Suitability For Isolation:
yes IEC 60947-1
Fire Resistance:
960°C IEC 60695-2-11
Ambient Air Temperature For Storage:
-50-85°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pollution Degree:
3
Magnetic Tripping Current:
1955-1955 A
Net Weight:
1.45 kg
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Color:
Gray RAL 7016)
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
$945.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose