Schneider Electric

Schneider Electric GV4PEM80S Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 100kA, thermal magnetic multifunction, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PEM80S
MPN:
GV4PEM80S
Condition:
New
Product Or Component Type:
motor circuit breaker
Circularity Profile:
ENVEOLI1704004EN
Warranty:
18 months
Pollution Degree:
3
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-1
Environmental Disclosure:
ENVPEP1704004EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Trip Unit Technology:
thermal-magnetic || electronic
Depth:
116 mm
Mechanical Durability:
40000 cycles
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
Ik Degree Of Protection:
IK07 IEC 62262
Weight:
1.45 kg
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Width:
81 mm
Ambient Air Temperature For Operation:
-25-70°C
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Height:
155 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Poles Description:
3P
Range:
TeSys Deca
Sustainable Offer Status:
Green Premium product
Device Application:
motor protection
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 30-30 kW 500 V AC 50/60 Hz || 37-37 kW 660...690 V AC 50/60 Hz || 45-45 kW 660...690 V AC 50/60 Hz || 55-55 kW 660...690 V AC 50/60 Hz || 30-30 kW 4
Country of Origin:
Poland
Device Short Name:
GV4PEM
Power Dissipation Per Pole:
4.6 W
Climatic Withstand:
IACS E10
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Control Type:
toggle
Operating Position:
any position
Fire Resistance:
960°C IEC 60695-2-11
Ambient Air Temperature For Storage:
-50-85°C
Maximum Operating Rate:
25 cyc/h
Rohs Exemption Information:
Yes
Range Of Product:
TeSys GV4
Mercury Free:
Yes
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Ip Degree Of Protection:
IP40 IEC 60529
Phase Failure Sensitivity:
yes IEC 60947-4-1
Electrical Durability:
14000 cycles AC-3 440 V In/2 || 7000 cycles AC-3 440 V In
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
1.45 kg
$1,642.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose