Schneider Electric

Schneider Electric HDA260904 Circuit breaker, PowerPacT H, 90A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, BC

(No reviews yet) Write a Review
SKU:
HDA260904
MPN:
HDA260904
Condition:
New
Wire Stripping Length:
16 mm
Depth:
86 mm
Country of Origin:
United States
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Continuous Current Rating:
0.8
Electrical Connection:
I-Line connection, line || lugs, load
Length:
16 mm
Ambient Air Temperature For Storage:
-50-85°C
Net Weight:
2.2 kg
Eu Rohs Directive:
Compliant with Exemptions
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Color:
Black
Mounting Support:
bracket
Product Certifications:
UL || CSA || NOM
Mounting Height:
3 in
Pollution Degree:
3 IEC 60947-1
Environmental Disclosure:
ENVPEP2206027EN
Magnetic Tripping Current:
1450-1450 A
Phase Connection:
BC
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Terminal Identifier:
AL150HD
Device Application:
distribution
Network Frequency:
50/60 Hz
Height:
163 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quantity Per Set:
1
Suitability For Isolation:
yes IEC 60947-2
Sustainable Offer Status:
Green Premium product
Mounting Mode:
I-Line bracket)
Poles Description:
2P
Weight:
2.2 kg
Circuit Breaker Application:
HACR rated
Communication Interface:
Modbus || Ethernet
Mercury Free:
Yes
Breaking Capacity Code:
D
Circularity Profile:
ENVEOLI2206027EN
Warranty:
18 months
Utilisation Category:
category A
Line Rated Current:
90-90 A
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
$1,088.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 90A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose