Schneider Electric

Schneider Electric HDA261256 Circuit breaker, PowerPacT H, 125A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB

(No reviews yet) Write a Review
SKU:
HDA261256
MPN:
HDA261256
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
I-Line bracket)
Weight:
2.2 kg
Eu Rohs Directive:
Compliant with Exemptions
Continuous Current Rating:
0.8
Mercury Free:
Yes
Product Certifications:
UL || CSA || NOM
Range:
PowerPact
Net Weight:
2.2 kg
Magnetic Hold Current:
900 A
Environmental Disclosure:
ENVPEP2206027EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Depth:
86 mm
Color:
Black
Quality Labels:
CE
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Line Rated Current:
125-125 A
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Support:
bracket
Terminal Identifier:
AL150HD
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Suitability For Isolation:
yes IEC 60947-2
Height:
163 mm
Length:
16 mm
Pollution Degree:
3 IEC 60947-1
Country of Origin:
United States
Local Signaling:
switched off (OFF) 1 trip indicator green)
Quantity Per Set:
1
Ambient Air Temperature For Storage:
-50-85°C
Ambient Air Temperature For Operation:
-25-70°C
Product Or Component Type:
circuit breaker
Protected Poles Description:
2t
Utilisation Category:
category A
Magnetic Tripping Current:
1700-1700 A
Rohs Exemption Information:
Yes
Control Type:
toggle
Circuit Breaker Application:
HACR rated
Poles Description:
2P
Circularity Profile:
ENVEOLI2206027EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Wire Stripping Length:
16 mm
Electrical Connection:
I-Line connection, line || lugs, load
Ip Degree Of Protection:
front cover IP40 IEC 60529
$2,195.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 125A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a CB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose