Schneider Electric

Schneider Electric HDA36060U44X Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 14kA, I-Line, Micrologic 6.2A, 80%, ABC

(No reviews yet) Write a Review
SKU:
HDA36060U44X
MPN:
HDA36060U44X
Condition:
New
Device Application:
distribution
Environmental Disclosure:
ENVPEP2206028EN
Ambient Air Temperature For Operation:
-25-70°C
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Weight:
2.2 kg
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Quantity Per Set:
1
Height:
163 mm
Protected Poles Description:
3t
Terminal Identifier:
AL150HD
Depth:
86 mm
Height:
4.5 in
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quality Labels:
CE
Utilisation Category:
category A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Phase Connection:
ABC
Eu Rohs Directive:
Compliant with Exemptions
Communication Interface:
Modbus || Ethernet
Mounting Support:
bracket
Warranty:
18 months
Wire Stripping Length:
16 mm
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Rohs Exemption Information:
Yes
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity Code:
D
Width:
104 mm
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Certifications:
UL || CSA || NOM
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Length:
16 mm
Circuit Breaker Application:
HACR rated
Product Name:
PowerPact H
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Poles Description:
3P
Control Type:
toggle
Line Rated Current:
60-60 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40 IEC 60529
Range:
PowerPact
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.2 A, LSIG
Electrical Connection:
I-Line connection, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$2,902.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose