Schneider Electric

Schneider Electric HDA36150U53X Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 14kA, I-Line, Micrologic 5.2E, 80%, ABC

(No reviews yet) Write a Review
SKU:
HDA36150U53X
MPN:
HDA36150U53X
Condition:
New
Communication Interface:
Modbus || Ethernet
Mounting Mode:
I-Line bracket)
Mounting Support:
bracket
Circuit Breaker Application:
HACR rated
Ip Degree Of Protection:
front cover IP40 IEC 60529
Trip Unit Name:
MicroLogic 5.2 E
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ambient Air Temperature For Storage:
-50-85°C
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Operation:
-25-70°C
Rohs Exemption Information:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Protected Poles Description:
3t
Pollution Degree:
3 IEC 60947-1
Line Rated Current:
150-150 A
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Length:
16 mm
Product Certifications:
UL || CSA || NOM
Suitability For Isolation:
yes IEC 60947-2
Height:
163 mm
Quantity Per Set:
1
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Technology:
electronic, energy, MicroLogic 5.2 E, LSI
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI1311007EN_V2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Device Application:
distribution
Phase Connection:
ABC
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Height:
4.5 in
Pvc Free:
Yes
Weight:
2.2 kg
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Electrical Connection:
I-Line connection, line || lugs, load
Control Type:
toggle
Environmental Disclosure:
ENVPEP1311007EN
Net Weight:
2.2 kg
Range:
PowerPact
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Terminal Identifier:
AL150HD
Product Or Component Type:
circuit breaker
Breaking Capacity Code:
D
Country of Origin:
United States
$4,118.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Energy with a 5.2E trip unit and an LSI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose