Schneider Electric

Schneider Electric HDF26090 Circuit breaker, PowerPacT H, 90A, 2 pole, 600VAC, 14kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HDF26090
MPN:
HDF26090
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Warranty:
18 months
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Line Rated Current:
90-90 A
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Height:
163 mm
Net Weight:
2.2 kg
Device Application:
distribution
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Magnetic Tripping Current:
1450-1450 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Wire Stripping Length:
16 mm
Environmental Disclosure:
ENVPEP2206027EN
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Local Signaling:
switched off (OFF) 1 trip indicator green)
Mounting Mode:
unit mount busbar)
Product Or Component Type:
circuit breaker
Pvc Free:
Yes
Mounting Support:
busbar
Weight:
2.2 kg
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connection:
busbar connection, line || busbar connection, load
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Communication Interface:
Modbus || Ethernet
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Trip Unit Technology:
thermal-magnetic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Continuous Current Rating:
0.8
Product Name:
PowerPact H
Ambient Air Temperature For Operation:
-25-70°C
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40 IEC 60529
Quantity Per Set:
1
Country of Origin:
United States
Poles Description:
2P
Utilisation Category:
category A
Terminal Identifier:
AL150HD
Mercury Free:
Yes
Depth:
86 mm
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity Code:
D
Range:
PowerPact
Ambient Air Temperature For Storage:
-50-85°C
Suitability For Isolation:
yes IEC 60947-2
$1,593.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT H, 90A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.