Schneider Electric

Schneider Electric HDF36100 Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 14kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HDF36100
MPN:
HDF36100
Condition:
New
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL150HD
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ip Degree Of Protection:
front cover IP40 IEC 60529
Electrical Connection:
busbar connection, line || busbar connection, load
Country of Origin:
United States
Mounting Support:
busbar
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Protected Poles Description:
3t
Poles Description:
3P
Magnetic Tripping Current:
1700-1700 A
Pvc Free:
Yes
Local Signaling:
switched off (OFF) 1 trip indicator green)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Communication Interface:
Modbus || Ethernet
Ambient Air Temperature For Storage:
-50-85°C
Environmental Disclosure:
ENVPEP2206027EN
Pollution Degree:
3 IEC 60947-1
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Wire Stripping Length:
16 mm
Quality Labels:
CE
Depth:
86 mm
Sustainable Offer Status:
Green Premium product
Weight:
2.2 kg
Eu Rohs Directive:
Compliant with Exemptions
Quantity Per Set:
1
Rohs Exemption Information:
Yes
Circularity Profile:
ENVEOLI2206027EN
Color:
Black
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Net Weight:
2.2 kg
Trip Unit Technology:
thermal-magnetic
Product Name:
PowerPact H
Control Type:
toggle
Ambient Air Temperature For Operation:
-25-70°C
Range:
PowerPact
Mercury Free:
Yes
Length:
16 mm
Magnetic Hold Current:
900 A
Warranty:
18 months
Mounting Mode:
unit mount busbar)
$1,328.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.