Schneider Electric

Schneider Electric HDF36100U44X Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 14kA, busbar, Micrologic 6.2A, 80%

(No reviews yet) Write a Review
SKU:
HDF36100U44X
MPN:
HDF36100U44X
Condition:
New
Ambient Air Temperature For Storage:
-50-85°C
Continuous Current Rating:
0.8
Control Type:
toggle
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Length:
16 mm
Protected Poles Description:
3t
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Device Application:
distribution
Product Name:
PowerPact H
Electrical Connection:
busbar connection, line || busbar connection, load
Communication Interface:
Modbus || Ethernet
Pvc Free:
Yes
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Pollution Degree:
3 IEC 60947-1
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity Code:
D
Ambient Air Temperature For Operation:
-25-70°C
Circuit Breaker Application:
HACR rated
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL150HD
Wire Stripping Length:
16 mm
Suitability For Isolation:
yes IEC 60947-2
Product Certifications:
UL || CSA || NOM
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Support:
busbar
Trip Unit Name:
MicroLogic 6.2 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
unit mount busbar)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Poles Description:
3P
Rohs Exemption Information:
Yes
Country of Origin:
United States
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Color:
Black
Height:
163 mm
Quantity Per Set:
1
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Quality Labels:
CE
Environmental Disclosure:
ENVPEP2206028EN
Range:
PowerPact
Depth:
86 mm
Product Or Component Type:
circuit breaker
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
$4,486.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.