Schneider Electric

Schneider Electric HDL36060U31XSA Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 14kA, lugs, Micrologic 3.2, 80%, shunt

(No reviews yet) Write a Review
SKU:
HDL36060U31XSA
MPN:
HDL36060U31XSA
Condition:
New
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pvc Free:
Yes
Line Rated Current:
60-60 A
Electrical Connection:
lugs, line || lugs, load
Mercury Free:
Yes
Breaking Capacity Code:
D
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Eu Rohs Directive:
Compliant with Exemptions
Terminal Identifier:
AL150HD
Communication Interface:
Modbus || Ethernet
Control Type:
toggle
Poles Description:
3P
Ip Degree Of Protection:
front cover IP40 IEC 60529
Continuous Current Rating:
0.8
Warranty:
18 months
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Length:
16 mm
Product Name:
PowerPact H
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
unit mount lug)
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Height:
163 mm
Trip Unit Name:
MicroLogic 3.2
Circularity Profile:
ENVEOLI2206028EN
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Environmental Disclosure:
ENVPEP2206028EN
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Suitability For Isolation:
yes IEC 60947-2
Network Frequency:
50/60 Hz
Circuit Breaker Application:
HACR rated
Color:
Black
Protected Poles Description:
3t
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Quality Labels:
CE
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Ambient Air Temperature For Storage:
-50-85°C
Mounting Support:
lug
Wire Stripping Length:
16 mm
Device Application:
distribution
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pollution Degree:
3 IEC 60947-1
Net Weight:
2.2 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$1,964.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose