Schneider Electric

Schneider Electric HDL36060U54X Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 14kA, lugs, Micrologic 6.2E, 80%

(No reviews yet) Write a Review
SKU:
HDL36060U54X
MPN:
HDL36060U54X
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Length:
16 mm
Product Certifications:
UL || CSA || NOM
Trip Unit Technology:
electronic, energy, MicroLogic 6.2 E, LSIG
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
Net Weight:
2.2 kg
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Depth:
86 mm
Country of Origin:
United States
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity Code:
D
Product Name:
PowerPact H
Ip Degree Of Protection:
front cover IP40 IEC 60529
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Communication Interface:
Modbus || Ethernet
Mercury Free:
Yes
Electrical Connection:
lugs, line || lugs, load
Utilisation Category:
category A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Control Type:
toggle
Color:
Black
Weight:
2.2 kg
Circularity Profile:
ENVEOLI2206028EN
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Device Application:
distribution
Product Or Component Type:
circuit breaker
Warranty:
18 months
Network Frequency:
50/60 Hz
Line Rated Current:
60-60 A
Environmental Disclosure:
ENVPEP2206028EN
Terminal Identifier:
AL150HD
Quantity Per Set:
1
Range:
PowerPact
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
$4,666.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Energy with a 6.2E trip unit and an LSIG function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose