Schneider Electric

Schneider Electric HGA36100U44X Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.2A, 80%, ABC

(No reviews yet) Write a Review
SKU:
HGA36100U44X
MPN:
HGA36100U44X
Condition:
New
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Electrical Connection:
I-Line connection, line || lugs, load
Trip Unit Name:
MicroLogic 6.2 A
Weight:
2.2 kg
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Protected Poles Description:
3t
Product Name:
PowerPact H
Mounting Support:
bracket
Ambient Air Temperature For Storage:
-50-85°C
Utilisation Category:
category A
Mounting Mode:
I-Line bracket)
Communication Interface:
Modbus || Ethernet
Product Or Component Type:
circuit breaker
Range:
PowerPact
Pvc Free:
Yes
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Terminal Identifier:
AL150HD
Rohs Exemption Information:
Yes
Quality Labels:
CE
Warranty:
18 months
Poles Description:
3P
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Height:
163 mm
Eu Rohs Directive:
Compliant with Exemptions
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
86 mm
Circularity Profile:
ENVEOLI2206028EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Height:
4.5 in
Suitability For Isolation:
yes IEC 60947-2
Quantity Per Set:
1
Ambient Air Temperature For Operation:
-25-70°C
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Country of Origin:
United States
Phase Connection:
ABC
Continuous Current Rating:
0.8
Color:
Black
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Wire Stripping Length:
16 mm
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40 IEC 60529
$3,549.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose