Schneider Electric

Schneider Electric HGF26100 Circuit breaker, PowerPacT H, 100A, 2 pole, 600VAC, 18kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HGF26100
MPN:
HGF26100
Condition:
New
Ambient Air Temperature For Storage:
-50-85°C
Country of Origin:
United States
Pollution Degree:
3 IEC 60947-1
Continuous Current Rating:
0.8
Weight:
2.2 kg
Communication Interface:
Modbus || Ethernet
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Device Application:
distribution
Electrical Connection:
busbar connection, line || busbar connection, load
Ambient Air Temperature For Operation:
-25-70°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Magnetic Hold Current:
900 A
Protected Poles Description:
2t
Environmental Disclosure:
ENVPEP2206027EN
Network Frequency:
50/60 Hz
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Magnetic Tripping Current:
1700-1700 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Width:
104 mm
Circularity Profile:
ENVEOLI2206027EN
Line Rated Current:
100-100 A
Pvc Free:
Yes
Depth:
86 mm
Product Or Component Type:
circuit breaker
Quality Labels:
CE
Mounting Mode:
unit mount busbar)
Eu Rohs Directive:
Compliant with Exemptions
Product Certifications:
UL || CSA || NOM
Control Type:
toggle
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL150HD
Length:
16 mm
Breaking Capacity Code:
G
Local Signaling:
switched off (OFF) 1 trip indicator green)
Wire Stripping Length:
16 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Color:
Black
Rohs Exemption Information:
Yes
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Support:
busbar
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Net Weight:
2.2 kg
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
$2,245.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT H, 100A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.