Schneider Electric

Schneider Electric HGL36050SA Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%, shunt

(No reviews yet) Write a Review
SKU:
HGL36050SA
MPN:
HGL36050SA
Condition:
New
Wire Stripping Length:
16 mm
Ambient Air Temperature For Operation:
-25-70°C
Magnetic Tripping Current:
850-850 A
Mercury Free:
Yes
Quantity Per Set:
1
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85°C
Circuit Breaker Application:
HACR rated
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Communication Interface:
Modbus || Ethernet
Control Type:
toggle
Local Signaling:
switched off (OFF) 1 trip indicator green)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
Poles Description:
3P
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Name:
PowerPact H
Country of Origin:
United States
Electrical Connection:
lugs, line || lugs, load
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Trip Unit Technology:
thermal-magnetic
Line Rated Current:
50-50 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Sustainable Offer Status:
Green Premium product
Depth:
86 mm
Mounting Support:
lug
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Net Weight:
2.2 kg
Weight:
2.2 kg
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Rohs Exemption Information:
Yes
Length:
16 mm
Terminal Identifier:
AL150HD
Eu Rohs Directive:
Compliant with Exemptions
Magnetic Hold Current:
400 A
Color:
Black
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Quality Labels:
CE
Continuous Current Rating:
0.8
Network Frequency:
50/60 Hz
Pvc Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
$2,210.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 50A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose