Schneider Electric

Schneider Electric HGL36060U43X Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 18kA, lugs, Micrologic 5.2A, 80%

(No reviews yet) Write a Review
SKU:
HGL36060U43X
MPN:
HGL36060U43X
Condition:
New
Depth:
86 mm
Circuit Breaker Application:
HACR rated
Terminal Identifier:
AL150HD
Network Frequency:
50/60 Hz
Product Name:
PowerPact H
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Ambient Air Temperature For Operation:
-25-70°C
Utilisation Category:
category A
Environmental Disclosure:
ENVPEP2206028EN
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Length:
16 mm
Line Rated Current:
60-60 A
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Circularity Profile:
ENVEOLI2206028EN
Protected Poles Description:
3t
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Color:
Black
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
16 mm
Warranty:
18 months
Rohs Exemption Information:
Yes
Device Application:
distribution
Range:
PowerPact
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Poles Description:
3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Ambient Air Temperature For Storage:
-50-85°C
Quality Labels:
CE
Mounting Support:
lug
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Country of Origin:
United States
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Breaking Capacity Code:
G
Weight:
2.2 kg
Continuous Current Rating:
0.8
Quantity Per Set:
1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Communication Interface:
Modbus || Ethernet
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
2.2 kg
Control Type:
toggle
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Certifications:
UL || CSA || NOM
$2,436.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 5.2A trip unit and an LSI function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose