Schneider Electric

Schneider Electric HGL36150U43X Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 18kA, lugs, Micrologic 5.2A, 80%

(No reviews yet) Write a Review
SKU:
HGL36150U43X
MPN:
HGL36150U43X
Condition:
New
Quantity Per Set:
1
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Support:
lug
Protected Poles Description:
3t
Control Type:
toggle
Poles Description:
3P
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Product Or Component Type:
circuit breaker
Width:
104 mm
Environmental Disclosure:
ENVPEP2206028EN
Utilisation Category:
category A
Product Certifications:
UL || CSA || NOM
Electrical Connection:
lugs, line || lugs, load
Wire Stripping Length:
16 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Continuous Current Rating:
0.8
Rohs Exemption Information:
Yes
Color:
Black
Mercury Free:
Yes
Depth:
86 mm
Circuit Breaker Application:
HACR rated
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Suitability For Isolation:
yes IEC 60947-2
Circularity Profile:
ENVEOLI2206028EN
Range:
PowerPact
Mounting Mode:
unit mount lug)
Ambient Air Temperature For Operation:
-25-70°C
Quality Labels:
CE
Net Weight:
2.2 kg
Terminal Identifier:
AL150HD
Pollution Degree:
3 IEC 60947-1
Trip Unit Name:
MicroLogic 5.2 A
Line Rated Current:
150-150 A
Breaking Capacity Code:
G
Country of Origin:
United States
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Communication Interface:
Modbus || Ethernet
Device Application:
distribution
Height:
163 mm
Eu Rohs Directive:
Compliant with Exemptions
$4,542.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 5.2A trip unit and an LSI function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose