Schneider Electric HGL36150U44X Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 18kA, lugs, Micrologic 6.2A, 80%
Schneider Electric
$5,262.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Net Weight:
- 2.2 kg
- Weight:
- 2.2 kg
- Wire Stripping Length:
- 16 mm
- Width:
- 104 mm
- Utilisation Category:
- category A
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Local Signaling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Continuous Current Rating:
- 0.8
- Trip Unit Name:
- MicroLogic 6.2 A
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Mercury Free:
- Yes
- Terminal Identifier:
- AL150HD
- Pollution Degree:
- 3 IEC 60947-1
- Product Certifications:
- UL || CSA || NOM
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Operation:
- -25-70°C
- Environmental Disclosure:
- ENVPEP2206028EN
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Communication Interface:
- Modbus || Ethernet
- Length:
- 16 mm
- Circularity Profile:
- ENVEOLI2206028EN
- Quality Labels:
- CE
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ambient Air Temperature For Storage:
- -50-85°C
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Country of Origin:
- United States
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Mounting Support:
- lug
- Electrical Connection:
- lugs, line || lugs, load
- Range:
- PowerPact
- Network Frequency:
- 50/60 Hz
- Sustainable Offer Status:
- Green Premium product
- Pvc Free:
- Yes
- Line Rated Current:
- 150-150 A
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Suitability For Isolation:
- yes IEC 60947-2
- Poles Description:
- 3P
- Quantity Per Set:
- 1
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Breaking Capacity Code:
- G
- Control Type:
- toggle
- Rohs Exemption Information:
- Yes
- Device Application:
- distribution
- Mounting Mode:
- unit mount lug)
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489