Schneider Electric

Schneider Electric HGP36080 Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
HGP36080
MPN:
HGP36080
Condition:
New
Quality Labels:
CE
Wire Stripping Length:
16 mm
Mounting Support:
lug
Quantity Per Set:
1
Protected Poles Description:
3t
Magnetic Hold Current:
800 A
Product Or Component Type:
circuit breaker
Warranty:
18 months
Continuous Current Rating:
0.8
Ip Degree Of Protection:
front cover IP40 IEC 60529
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant with Exemptions
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Terminal Identifier:
AL150HD
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signaling:
switched off (OFF) 1 trip indicator green)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Width:
104 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206027EN
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Rohs Exemption Information:
Yes
Utilisation Category:
category A
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Suitability For Isolation:
yes IEC 60947-2
Color:
Black
Product Certifications:
UL || CSA || NOM
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Control Type:
toggle
Pollution Degree:
3 IEC 60947-1
Communication Interface:
Modbus || Ethernet
Mounting Mode:
unit mount lug)
Breaking Capacity Code:
G
Network Frequency:
50/60 Hz
Trip Unit Technology:
thermal-magnetic
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Mercury Free:
Yes
Electrical Connection:
terminal nut, line || lugs, load
Weight:
2.2 kg
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Poles Description:
3P
Device Application:
distribution
Net Weight:
2.2 kg
Country of Origin:
United States
$1,701.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 80A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose