Schneider Electric

Schneider Electric HJA360306 Circuit breaker, PowerPacT H, 30A, 3 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, CBA

(No reviews yet) Write a Review
SKU:
HJA360306
MPN:
HJA360306
Condition:
New
Height:
163 mm
Mounting Support:
bracket
Circuit Breaker Application:
HACR rated
Line Rated Current:
30-30 A
Phase Connection:
CBA
Suitability For Isolation:
yes IEC 60947-2
Magnetic Tripping Current:
750-750 A
Height:
4.5 in
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Certifications:
UL || CSA || NOM
Network Frequency:
50/60 Hz
Mounting Mode:
I-Line bracket)
Rohs Exemption Information:
Yes
Mounting Height:
4.5 in
Ambient Air Temperature For Storage:
-50-85°C
Mercury Free:
Yes
Weight:
2.2 kg
Quality Labels:
CE
Quantity Per Set:
1
Continuous Current Rating:
0.8
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus || Ethernet
Breaking Capacity Code:
J
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Color:
Black
Magnetic Hold Current:
350 A
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Electrical Connection:
I-Line connection, line || lugs, load
Country of Origin:
United States
Product Name:
PowerPact H
Protected Poles Description:
3t
Poles Description:
3P
Local Signaling:
switched off (OFF) 1 trip indicator green)
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
Control Type:
toggle
Terminal Identifier:
AL150HD
Net Weight:
2.2 kg
Wire Stripping Length:
16 mm
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
thermal-magnetic
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Utilisation Category:
category A
Environmental Disclosure:
ENVPEP2206027EN
Range:
PowerPact
$1,988.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 30A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a CBA phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose