Schneider Electric

Schneider Electric HJA36100SN Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, shunt, ABC

(No reviews yet) Write a Review
SKU:
HJA36100SN
MPN:
HJA36100SN
Condition:
New
Magnetic Hold Current:
900 A
Protected Poles Description:
3t
Wire Stripping Length:
16 mm
Height:
163 mm
Phase Connection:
ABC
Net Weight:
2.2 kg
Product Or Component Type:
circuit breaker
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
-25-70°C
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Depth:
86 mm
Length:
16 mm
Height:
4.5 in
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Line Rated Current:
100-100 A
Range:
PowerPact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weight:
2.2 kg
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Trip Unit Technology:
thermal-magnetic
Product Name:
PowerPact H
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Mounting Mode:
I-Line bracket)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Local Signaling:
switched off (OFF) 1 trip indicator green)
Sustainable Offer Status:
Green Premium product
Breaking Capacity Code:
J
Mounting Support:
bracket
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL150HD
Communication Interface:
Modbus || Ethernet
Accessory / Separate Part Type:
shunt trip 12 V DC compartment
Suitability For Isolation:
yes IEC 60947-2
Pvc Free:
Yes
Circularity Profile:
ENVEOLI2206027EN
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40 IEC 60529
Warranty:
18 months
Color:
Black
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP2206027EN
Poles Description:
3P
Width:
104 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Device Application:
distribution
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Magnetic Tripping Current:
1700-1700 A
$4,413.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 12VDC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose