Schneider Electric

Schneider Electric HJA361106 Circuit breaker, PowerPacT H, 110A, 3 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, CBA

(No reviews yet) Write a Review
SKU:
HJA361106
MPN:
HJA361106
Condition:
New
Trip Unit Technology:
thermal-magnetic
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
front cover IP40 IEC 60529
Wire Stripping Length:
16 mm
Quantity Per Set:
1
Sustainable Offer Status:
Green Premium product
Electrical Connection:
I-Line connection, line || lugs, load
Breaking Capacity Code:
J
Rohs Exemption Information:
Yes
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
86 mm
Mounting Mode:
I-Line bracket)
Protected Poles Description:
3t
Product Or Component Type:
circuit breaker
Range:
PowerPact
Phase Connection:
CBA
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ambient Air Temperature For Storage:
-50-85°C
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Height:
4.5 in
Line Rated Current:
110-110 A
Ambient Air Temperature For Operation:
-25-70°C
Local Signaling:
switched off (OFF) 1 trip indicator green)
Circuit Breaker Application:
HACR rated
Magnetic Tripping Current:
1700-1700 A
Continuous Current Rating:
0.8
Device Application:
distribution
Suitability For Isolation:
yes IEC 60947-2
Pvc Free:
Yes
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Poles Description:
3P
Pollution Degree:
3 IEC 60947-1
Control Type:
toggle
Network Frequency:
50/60 Hz
Height:
163 mm
Product Name:
PowerPact H
Mounting Height:
4.5 in
Product Certifications:
UL || CSA || NOM
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
$5,432.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 110A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a CBA phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose