Protected Poles Description:
3t
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Installed Device:
trip unit field installable
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
Magnetic Tripping Current:
750-750 A
Quality Labels:
CE
Mounting Support:
lug
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Range:
PowerPact
Color:
Black
Circuit Breaker Application:
HACR rated
Control Type:
toggle
Line Rated Current:
30-30 A
Ambient Air Temperature For Storage:
-50-85°C
Mounting Mode:
unit mount lug)
Warranty:
18 months
Wire Stripping Length:
16 mm
Communication Interface:
Modbus || Ethernet
Device Application:
distribution
Pollution Degree:
3 IEC 60947-1
Net Weight:
2.2 kg
Suitability For Isolation:
yes IEC 60947-2
Height:
163 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Name:
PowerPact H
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Circularity Profile:
ENVEOLI2206027EN
Poles Description:
3P
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Country of Origin:
United States
Trip Unit Technology:
thermal-magnetic
Breaking Capacity Code:
J
Depth:
86 mm
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
category A
Rohs Exemption Information:
Yes
Width:
104 mm
Ambient Air Temperature For Operation:
-25-70°C
Terminal Identifier:
AL150HD
Quantity Per Set:
1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
$2,923.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 30A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit allows field-interchangeable trip units. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose