Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Communication Interface:
Modbus || Ethernet
Depth:
86 mm
Warranty:
18 months
Weight:
2.2 kg
Height:
163 mm
Line Rated Current:
50-50 A
Device Application:
distribution
Terminal Identifier:
AL150HD
Environmental Disclosure:
ENVPEP2206027EN
Country of Origin:
United States
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Poles Description:
3P
Net Weight:
2.2 kg
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Trip Unit Technology:
thermal-magnetic
Quality Labels:
CE
Length:
16 mm
Sustainable Offer Status:
Green Premium product
Mounting Mode:
unit mount lug)
Utilisation Category:
category A
Ip Degree Of Protection:
front cover IP40 IEC 60529
Mercury Free:
Yes
Width:
104 mm
Ambient Air Temperature For Operation:
-25-70°C
[Ith] Conventional Free Air Thermal Current:
14-42 A
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Breaking Capacity Code:
J
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Electrical Connection:
lugs, line || lugs, load
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Ambient Air Temperature For Storage:
-50-85°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Protected Poles Description:
3t
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quantity Per Set:
1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-2
Control Type:
toggle
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Color:
Black
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Continuous Current Rating:
0.8
Mounting Support:
lug
Product Certifications:
UL || CSA || NOM
Product Or Component Type:
Motor Circuit Protector
$2,102.00

Description

PowerPacT H-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. This PowerPacT H, 50A, 3 pole, motor protector has a breaking capacity of 25kA at 600VAC. This unit has lugs on both the line and load side. These motor protectors accept the same accessories and terminals as PowerPacT H circuit breakers. This breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.