Schneider Electric

Schneider Electric HL1IMA12C Surge protection device, Surgelogic, HL, 120kA, 120/240 VAC, 1 phase, 3 wire, SPD type 2

(No reviews yet) Write a Review
SKU:
HL1IMA12C
MPN:
HL1IMA12C
Condition:
New
Breaking Capacity Code:
HL
Country of Origin:
United States
Depth:
142.1 mm
[Uc] Maximum Continuous Operating Voltage:
150 V
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
Connections - Terminals:
I-Line line || lugs ground AWG 6 copper 4 N.m || lugs neutral AWG 6 copper 4 N.m
Device Short Name:
IMA
Eu Rohs Directive:
Compliant with Exemptions
Trip Unit Technology:
thermal-magnetic
Length:
483 mm
Nema Degree Of Protection:
NEMA 2
Enclosure Material:
Gray painted sheet steel
Product Or Component Type:
surge protection device
Provided Equipment:
alarm enable/disable switch || surge counter || circuit-breaker
Wiring Configuration:
3-wire
Range Of Product:
Surgelogic
Number Of Poles:
3
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Mounting Support:
panel mounting
Rohs Exemption Information:
Yes
Breaking Capacity:
50 kA
Standards:
UL 1449:ed. 3 || UL 1283:ed. 5 || CSA C22.2 No 8:1986 || UL 96A:ed. 12 || UL 489:ed. 11 || CSA C22.2 No 5-09
Cable Length:
483 mm
Line Rated Current:
60 A
Phase:
1 phase
Surge Current:
120 kA
Short-Circuit Protection:
200 kA
[Ue] Rated Operational Voltage:
120/240 V AC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signaling:
status LED green per phase normal operation || status LED red per phase fault
$9,518.00

Description

Surgelogic™ internally mounted surge protection devices delivers specification grade performance for service entrance or critical branch I-Line panel applications. These multiphase systems provide suppression, enchanced EFI/RFI filtering for all critical modes inside electrical equipment, and shorter lead lengths with superior SPD performance. They provide better performance with a diagnostic interface with push to test diagnostic switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. These products have a 10 year product warranty and 10 modes of protection. This surge protection device is 1 phase, 3-wire + ground, 120/240 V, 50 kA breaking capacity, 120 kA surge current, and short circuit current rating of 200 kA. The device is engineered to UL 489 11th Edition, type 2 SPD and complies with UL 96A 12th Edition Master Label for Lightning Protection Systems.
View AllClose