Schneider Electric

Schneider Electric HL2IMA16C Surge protection device, Surgelogic, HL, 160kA, 208Y/120 VAC, 3 phase, 4 wire, SPD type 2

(No reviews yet) Write a Review
SKU:
HL2IMA16C
MPN:
HL2IMA16C
Condition:
New
Product Or Component Type:
surge protection device
Standards:
UL 1449:ed. 3 || UL 1283:ed. 5 || CSA C22.2 No 8:1986 || UL 96A:ed. 12 || UL 489:ed. 11 || CSA C22.2 No 5-09
Connections - Terminals:
I-Line line || lugs ground AWG 6 copper 4 N.m || lugs neutral AWG 6 copper 4 N.m
Cable Length:
483 mm
Trip Unit Technology:
thermal-magnetic
Breaking Capacity Code:
HL
Depth:
142.1 mm
[Uc] Maximum Continuous Operating Voltage:
150 V
Number Of Poles:
3
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Short Name:
IMA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Nema Degree Of Protection:
NEMA 2
Breaking Capacity:
50 kA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Provided Equipment:
alarm enable/disable switch || surge counter || circuit-breaker
Phase:
3 phase
Country of Origin:
Mexico
Rohs Exemption Information:
Yes
Range Of Product:
Surgelogic
Warranty:
18 months
Line Rated Current:
60 A
Local Signaling:
status LED green per phase normal operation || status LED red per phase fault
Surge Current:
160 kA
Mounting Support:
panel mounting
Short-Circuit Protection:
200 kA
Eu Rohs Directive:
Compliant with Exemptions
Wiring Configuration:
4-wire
[Ue] Rated Operational Voltage:
208Y/120 V AC
Length:
483 mm
$10,872.00

Description

Surgelogic™ EMA and EBA series SPDs offer a full range of externally mounted surge suppression solutions. These units are designed to provide surge suppression from service entrance panels to point-of-use equipment. US and Canadian UL® Listed to the UL 1449 standard. Complies with requirements of NEC® Article 285 and CSA 22.2 No. 8- M1986 as appropriate. Complies with UL 96A 12th Edition Master Label requirements for Lightning Protection Systems. This Surelogic SPD device is a three phase, 4-wire grounded wye system that has a peak surge current rating of 160 kA. This device has operational voltage of 208Y/120 Vac and has a short circuit rating of 200 kA. This SPD is in a NEMA 2 enclosure that is 308.9 tall, 341.9 mm wide and 142.1 mm deep.
View AllClose