Schneider Electric

Schneider Electric HLA260252 Circuit breaker, PowerPacT H, 25A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, AC

(No reviews yet) Write a Review
SKU:
HLA260252
MPN:
HLA260252
Condition:
New
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Application:
distribution
Magnetic Tripping Current:
750-750 A
Quantity Per Set:
1
Line Rated Current:
25-25 A
Ip Degree Of Protection:
front cover IP40 IEC 60529
Rohs Exemption Information:
Yes
Height:
163 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circuit Breaker Application:
HACR rated
Suitability For Isolation:
yes IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Weight:
2.2 kg
Continuous Current Rating:
0.8
Pvc Free:
Yes
Breaking Capacity Code:
L
Communication Interface:
Modbus || Ethernet
Height:
4.5 in
Circularity Profile:
ENVEOLI2206027EN
Mounting Height:
4.5 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Product Or Component Type:
circuit breaker
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Terminal Identifier:
AL150HD
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Color:
Black
Length:
16 mm
Mounting Mode:
I-Line bracket)
Environmental Disclosure:
ENVPEP2206027EN
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
toggle
Ambient Air Temperature For Storage:
-50-85°C
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Electrical Connection:
I-Line connection, line || lugs, load
Net Weight:
2.2 kg
Depth:
86 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Wire Stripping Length:
16 mm
Ambient Air Temperature For Operation:
-25-70°C
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Quality Labels:
CE
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Utilisation Category:
category A
$2,483.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 25A, 2 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose