Schneider Electric HLA260301 Circuit breaker, PowerPacT H, 30A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, AB
Schneider Electric
$5,586.75
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 30A, 2 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Product Name:
- PowerPact H
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Magnetic Hold Current:
- 350 A
- Magnetic Tripping Current:
- 750-750 A
- Rohs Exemption Information:
- Yes
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Height:
- 163 mm
- Terminal Identifier:
- AL150HD
- Weight:
- 2.2 kg
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Net Weight:
- 2.2 kg
- Eu Rohs Directive:
- Compliant
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Country of Origin:
- United States
- Mounting Mode:
- I-Line bracket)
- Control Type:
- toggle
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Height:
- 4.5 in
- Warranty:
- 18 months
- Mercury Free:
- Yes
- Environmental Disclosure:
- ENVPEP1311006EN
- Device Application:
- distribution
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Circularity Profile:
- ENVEOLI1311006EN
- Ambient Air Temperature For Operation:
- -25-70°C
- Circuit Breaker Application:
- HACR rated
- Color:
- Black
- Network Frequency:
- 50/60 Hz
- Length:
- 16 mm
- Local Signaling:
- switched off (OFF) 1 trip indicator green)
- Depth:
- 86 mm
- Quantity Per Set:
- 1
- Range:
- PowerPact
- Phase Connection:
- AB
- Poles Description:
- 2P
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity Code:
- L
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- UL || CSA || NOM
- Pvc Free:
- Yes
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Product Or Component Type:
- circuit breaker
- Communication Interface:
- Modbus || Ethernet
- Ambient Air Temperature For Storage:
- -50-85°C
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Pollution Degree:
- 3 IEC 60947-1