Schneider Electric

Schneider Electric HLA260504 Circuit breaker, PowerPacT H, 50A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, BC

(No reviews yet) Write a Review
SKU:
HLA260504
MPN:
HLA260504
Condition:
New
Line Rated Current:
50-50 A
Electrical Connection:
I-Line connection, line || lugs, load
Phase Connection:
BC
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Trip Unit Technology:
thermal-magnetic
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Mode:
I-Line bracket)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Support:
bracket
Ambient Air Temperature For Storage:
-50-85°C
Quality Labels:
CE
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Wire Stripping Length:
16 mm
Communication Interface:
Modbus || Ethernet
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Weight:
2.2 kg
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Product Or Component Type:
circuit breaker
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Poles Description:
2P
Net Weight:
2.2 kg
Pollution Degree:
3 IEC 60947-1
Depth:
86 mm
Ambient Air Temperature For Operation:
-25-70°C
Warranty:
18 months
Mounting Height:
4.5 in
Device Application:
distribution
Suitability For Isolation:
yes IEC 60947-2
Quantity Per Set:
1
Circuit Breaker Application:
HACR rated
Control Type:
toggle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Protected Poles Description:
2t
Breaking Capacity Code:
L
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Mercury Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Range:
PowerPact
Network Frequency:
50/60 Hz
Terminal Identifier:
AL150HD
Local Signaling:
switched off (OFF) 1 trip indicator green)
Continuous Current Rating:
0.8
Magnetic Hold Current:
400 A
Rohs Exemption Information:
Yes
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Utilisation Category:
category A
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
$3,724.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 50A, 2 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.