Schneider Electric

Schneider Electric HLA260602 Circuit breaker, PowerPacT H, 60A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, AC

(No reviews yet) Write a Review
SKU:
HLA260602
MPN:
HLA260602
Condition:
New
Color:
Black
Wire Stripping Length:
16 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Support:
bracket
Network Frequency:
50/60 Hz
Product Name:
PowerPact H
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Pvc Free:
Yes
Depth:
86 mm
Circularity Profile:
ENVEOLI2206027EN
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Length:
16 mm
Local Signaling:
switched off (OFF) 1 trip indicator green)
Suitability For Isolation:
yes IEC 60947-2
Mounting Height:
4.5 in
Device Application:
distribution
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Warranty:
18 months
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Weight:
2.2 kg
Quality Labels:
CE
Environmental Disclosure:
ENVPEP2206027EN
Poles Description:
2P
Height:
163 mm
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Operation:
-25-70°C
Net Weight:
2.2 kg
Mounting Mode:
I-Line bracket)
Ip Degree Of Protection:
front cover IP40 IEC 60529
Trip Unit Technology:
thermal-magnetic
Electrical Connection:
I-Line connection, line || lugs, load
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Breaking Capacity Code:
L
Circuit Breaker Application:
HACR rated
Magnetic Tripping Current:
1450-1450 A
Mercury Free:
Yes
Ambient Air Temperature For Storage:
-50-85°C
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Phase Connection:
AC
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Continuous Current Rating:
0.8
Country of Origin:
United States
Utilisation Category:
category A
$2,483.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 2 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.