Schneider Electric

Schneider Electric HLA360306 Circuit breaker, PowerPacT H, 30A, 3 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, CBA

(No reviews yet) Write a Review
SKU:
HLA360306
MPN:
HLA360306
Condition:
New
Height:
4.5 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Mounting Height:
4.5 in
Trip Unit Technology:
thermal-magnetic
Protected Poles Description:
3t
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Environmental Disclosure:
ENVPEP2206027EN
Weight:
2.2 kg
Quality Labels:
CE
Length:
16 mm
Product Name:
PowerPact H
Local Signaling:
switched off (OFF) 1 trip indicator green)
Color:
Black
Terminal Identifier:
AL150HD
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85°C
Mounting Support:
bracket
Utilisation Category:
category A
Ip Degree Of Protection:
front cover IP40 IEC 60529
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Communication Interface:
Modbus || Ethernet
Circuit Breaker Application:
HACR rated
Suitability For Isolation:
yes IEC 60947-2
Country of Origin:
United States
Height:
163 mm
Device Application:
distribution
Mounting Mode:
I-Line bracket)
Breaking Capacity Code:
L
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Magnetic Tripping Current:
750-750 A
Product Or Component Type:
circuit breaker
Phase Connection:
CBA
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range:
PowerPact
Wire Stripping Length:
16 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Circularity Profile:
ENVEOLI2206027EN
Control Type:
toggle
Mercury Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Depth:
86 mm
$2,993.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 30A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a CBA phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose