Schneider Electric

Schneider Electric HLA360356 Circuit breaker, PowerPacT H, 35A, 3 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, CBA

(No reviews yet) Write a Review
SKU:
HLA360356
MPN:
HLA360356
Condition:
New
Length:
16 mm
Product Certifications:
UL || CSA || NOM
Product Name:
PowerPact H
Mounting Height:
4.5 in
Local Signaling:
switched off (OFF) 1 trip indicator green)
Mercury Free:
Yes
Weight:
2.2 kg
Depth:
86 mm
Mounting Support:
bracket
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Ambient Air Temperature For Storage:
-50-85°C
Circularity Profile:
ENVEOLI2206027EN
Mounting Mode:
I-Line bracket)
Terminal Identifier:
AL150HD
Wire Stripping Length:
16 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
2.2 kg
Phase Connection:
CBA
Pollution Degree:
3 IEC 60947-1
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Breaking Capacity Code:
L
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Or Component Type:
circuit breaker
Range:
PowerPact
Control Type:
toggle
Network Frequency:
50/60 Hz
Magnetic Tripping Current:
850-850 A
Warranty:
18 months
Poles Description:
3P
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Quality Labels:
CE
Environmental Disclosure:
ENVPEP2206027EN
Trip Unit Technology:
thermal-magnetic
Sustainable Offer Status:
Green Premium product
Quantity Per Set:
1
Rohs Exemption Information:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Height:
163 mm
Circuit Breaker Application:
HACR rated
Country of Origin:
United States
Magnetic Hold Current:
400 A
Color:
Black
Electrical Connection:
I-Line connection, line || lugs, load
Continuous Current Rating:
0.8
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
$2,993.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 35A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a CBA phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.