Schneider Electric

Schneider Electric HLA36100U44X Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 6.2A, 80%, ABC

(No reviews yet) Write a Review
SKU:
HLA36100U44X
MPN:
HLA36100U44X
Condition:
New
Length:
16 mm
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Protected Poles Description:
3t
Line Rated Current:
100-100 A
Device Application:
distribution
Height:
4.5 in
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Quantity Per Set:
1
Sustainable Offer Status:
Green Premium product
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.2 A, LSIG
Ambient Air Temperature For Operation:
-25-70°C
Terminal Identifier:
AL150HD
Trip Unit Name:
MicroLogic 6.2 A
Utilisation Category:
category A
Ip Degree Of Protection:
front cover IP40 IEC 60529
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-50-85°C
Wire Stripping Length:
16 mm
Circuit Breaker Application:
HACR rated
Product Certifications:
UL || CSA || NOM
Net Weight:
2.2 kg
Breaking Capacity Code:
L
Range:
PowerPact
Phase Connection:
ABC
Height:
163 mm
Suitability For Isolation:
yes IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Country of Origin:
United States
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Height:
4.5 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Electrical Connection:
I-Line connection, line || lugs, load
Network Frequency:
50/60 Hz
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Magnetic Hold Current:
900 A
Control Type:
toggle
Continuous Current Rating:
0.8
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Quality Labels:
CE
Depth:
86 mm
$7,615.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose