Schneider Electric

Schneider Electric HRL36060U33X Circuit breaker, PowerPacT H, 60A, 3 pole, 600VAC, 100kA, lugs, Micrologic 3.2S, 80%

(No reviews yet) Write a Review
SKU:
HRL36060U33X
MPN:
HRL36060U33X
Condition:
New
Wire Stripping Length:
16 mm
Sustainable Offer Status:
Green Premium product
Product Name:
PowerPact H
Environmental Disclosure:
ENVPEP2206028EN
Ip Degree Of Protection:
front cover IP40 IEC 60529
Terminal Identifier:
AL150HD
Breaking Capacity Code:
R
Country of Origin:
United States
Trip Unit Name:
MicroLogic 3.2 S
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Quality Labels:
CE
Quantity Per Set:
1
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Device Application:
distribution
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pollution Degree:
3 IEC 60947-1
Length:
16 mm
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Trip Unit Technology:
electronic, standard, MicroLogic 3.2 S, LSI
Circuit Breaker Application:
HACR rated
Control Type:
toggle
Weight:
2.2 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
2.2 kg
Protected Poles Description:
3t
Breaking Capacity:
200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
Mercury Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Rohs Exemption Information:
Yes
Range:
PowerPact
Ambient Air Temperature For Operation:
-25-70°C
Ambient Air Temperature For Storage:
-50-85°C
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206028EN
Pvc Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
Suitability For Isolation:
yes IEC 60947-2
Poles Description:
3P
Product Certifications:
UL || CSA || NOM
Electrical Connection:
lugs, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ics] Rated Service Breaking Capacity:
150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
$6,324.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 100kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 100kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.