- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -25-70°C
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile:
- ENVEOLI1311007EN_V2
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Poles Description:
- 3P
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Protected Poles Description:
- 3t
- Suitability For Isolation:
- yes IEC 60947-2
- Eu Rohs Directive:
- Compliant
- Color:
- Black
- Electrical Connection:
- lugs, line || lugs, load
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2 S, LSI
- Product Or Component Type:
- circuit breaker
- Net Weight:
- 2.2 kg
- Device Application:
- distribution
- Utilisation Category:
- category A
- Communication Interface:
- Modbus || Ethernet
- Terminal Identifier:
- AL150HD
- Control Type:
- toggle
- Product Certifications:
- UL || CSA || NOM
- Product Name:
- PowerPact H
- Range:
- PowerPact
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Pvc Free:
- Yes
- Mounting Mode:
- unit mount lug)
- Pollution Degree:
- 3 IEC 60947-1
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85°C
- Breaking Capacity Code:
- R
- Depth:
- 86 mm
- Breaking Capacity:
- 200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Line Rated Current:
- 150-150 A
- Mounting Support:
- lug
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Sustainable Offer Status:
- Green Premium product
- [Ics] Rated Service Breaking Capacity:
- 150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Weight:
- 2.2 kg
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Network Frequency:
- 50/60 Hz
- Quality Labels:
- CE
- Environmental Disclosure:
- ENVPEP1311007EN
- Local Signaling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)