Schneider Electric

Schneider Electric JLF36250 Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 50kA, busbar, thermal magnetic, 80%

(No reviews yet) Write a Review
SKU:
JLF36250
MPN:
JLF36250
Condition:
New
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Protection Type:
overload protection || short-circuit protection
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Wire Stripping Length:
25 mm
Breaking Capacity Code:
L
Net Weight:
2.4 kg
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Ip Degree Of Protection:
front cover IP40
Quality Labels:
CE
Environmental Disclosure:
ENVPEP2206031EN
Width:
104 mm
Network Frequency:
50/60 Hz
Suitability For Isolation:
yes IEC 60947-2
Length:
25 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Mercury Free:
Yes
Poles Description:
3P
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Warranty:
18 months
Magnetic Hold Current:
1250 A
Magnetic Tripping Current:
2500-2500 A
Communication Interface:
Modbus
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Country of Origin:
United States
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connection:
busbar connection, line || busbar connection, load
Product Certifications:
UL || CSA || NOM
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Type:
toggle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Local Signaling:
switched off (OFF) 1 trip indicator green)
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
Eu Rohs Directive:
Compliant with Exemptions
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Weight:
2.4 kg
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Depth:
86 mm
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Mounting Mode:
unit mount busbar)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Terminal Identifier:
AL250JD
Trip Unit Technology:
thermal-magnetic
Circularity Profile:
ENVEOLI2206031EN
Product Or Component Type:
circuit breaker
$13,489.50

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose