Schneider Electric

Schneider Electric JLL36175LV Circuit breaker, PowerPacT J, 175A, 3 pole, 600VAC, 50kA, lugs, thermal magnetic, 80%, control wire OFF end

(No reviews yet) Write a Review
SKU:
JLL36175LV
MPN:
JLL36175LV
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Operation:
-25-70°C
Warranty:
18 months
Country of Origin:
Mexico
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Accessory / Separate Part Type:
control wire OFF end
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Continuous Current Rating:
0.8
Mounting Support:
lug
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Pvc Free:
Yes
Wire Stripping Length:
25 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circuit Breaker Application:
HACR rated
Magnetic Hold Current:
875 A
Control Type:
toggle
Environmental Disclosure:
ENVPEP2206031EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
86 mm
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
Mounting Mode:
unit mount lug)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Awg Gauge:
AWG 4...AWG 4/0 aluminium/copper terminal
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Network Frequency:
50/60 Hz
Protection Type:
overload protection || short-circuit protection
Suitability For Isolation:
yes IEC 60947-2
Local Signaling:
switched off (OFF) 1 trip indicator green)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Length:
25 mm
Electrical Connection:
lugs, line || lugs, load
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Magnetic Tripping Current:
1750-1750 A
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Circularity Profile:
ENVEOLI2206031EN
Trip Unit Technology:
thermal-magnetic
Ip Degree Of Protection:
front cover IP40
Communication Interface:
Modbus
Breaking Capacity Code:
L
Mercury Free:
Yes
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Line Rated Current:
175-175 A
Sustainable Offer Status:
Green Premium product
Net Weight:
2.4 kg
Utilisation Category:
category A
Weight:
2.4 kg
$7,139.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 175A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a control wire terminal on the load end. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.