Schneider Electric

Schneider Electric JLL36250LY Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 50kA, lugs, thermal magnetic, 80%, low amp lugs

(No reviews yet) Write a Review
SKU:
JLL36250LY
MPN:
JLL36250LY
Condition:
New
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Protection Type:
overload protection || short-circuit protection
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Network Frequency:
50/60 Hz
Quality Labels:
CE
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Product Or Component Type:
circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Suitability For Isolation:
yes IEC 60947-2
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Electrical Connection:
lugs, line || lugs, load
Pvc Free:
Yes
Magnetic Tripping Current:
2500-2500 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Rohs Exemption Information:
Yes
Mounting Mode:
unit mount lug)
Communication Interface:
Modbus
Environmental Disclosure:
ENVPEP2206031EN
Product Certifications:
UL || CSA || NOM
Pollution Degree:
3
Poles Description:
3P
Depth:
86 mm
Ambient Air Temperature For Storage:
-50-85°C
Utilisation Category:
category A
Length:
25 mm
Trip Unit Technology:
thermal-magnetic
Ambient Air Temperature For Operation:
-25-70°C
Warranty:
18 months
Ip Degree Of Protection:
front cover IP40
Mercury Free:
Yes
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Accessory / Separate Part Type:
low amperage lug
Net Weight:
2.4 kg
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Country of Origin:
United States
Continuous Current Rating:
0.8
Line Rated Current:
250-250 A
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Weight:
2.4 kg
$8,993.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.