Schneider Electric JRA36250U43X Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 100kA, I-Line, Micrologic 5.2A, 80%, ABC
Schneider Electric
$17,341.50
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides Micrologic Ammeter with a 5.2A trip unit and an LSI function with a breaking capacity of 100kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 100kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Circuit Breaker Application:
- HACR rated
- Mounting Support:
- bracket
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Height:
- 4.5 in
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Communication Interface:
- Modbus
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Storage:
- -50-85°C
- Phase Connection:
- ABC
- Mounting Mode:
- I-Line bracket)
- Height:
- 191 mm
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Poles Description:
- 3P
- Breaking Capacity Code:
- R
- Mounting Height:
- 4.5 in
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Net Weight:
- 2.4 kg
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Quality Labels:
- CE
- Ambient Air Temperature For Operation:
- -25-70°C
- Eu Rohs Directive:
- Compliant with Exemptions
- Continuous Current Rating:
- 0.8
- Circularity Profile:
- ENVEOLI2206032EN
- Mercury Free:
- Yes
- Line Rated Current:
- 250-250 A
- Product Certifications:
- UL || CSA || NOM
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Suitability For Isolation:
- yes IEC 60947-2
- Utilisation Category:
- category A
- Weight:
- 2.4 kg
- Length:
- 25 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Local Signaling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm 1 LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Pollution Degree:
- 3
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Breaking Capacity:
- 200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
- [Ics] Rated Service Breaking Capacity:
- 150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Electrical Connection:
- I-Line connection, line || lugs, load
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Ip Degree Of Protection:
- front cover IP40
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 5.2 A, LSI
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Terminal Identifier:
- AL250JD
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Protection Type:
- overload protection || short-circuit protection