Schneider Electric

Schneider Electric LC1D098BD IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D098BD
MPN:
LC1D098BD
Condition:
New
Weight:
0.525 kg
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Circularity Profile:
ENVEOLI1102030EN
Compatibility Code:
LC1D
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Control Circuit Type:
DC standard
Ip Degree Of Protection:
IP20 front face IEC 60529
[Uc] Control Circuit Voltage:
24 V DC
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition:
1 NO + 1 NC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-60°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Pollution Degree:
3
Protective Cover:
with
Electrical Durability:
0.3 Mcycles 20 A AC-1 <= 690 V
Minimum Switching Current:
5 mA for Signaling circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Fire Resistance:
850°C IEC 60695-2-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 250 V DC
Rohs Exemption Information:
Yes
Net Weight:
0.525 kg
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Overvoltage Category:
III
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Time Constant:
28 ms
Pole Contact Composition:
2 NO + 2 NC
Minimum Switching Voltage:
17 V for Signaling circuit
Warranty:
18 months
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Poles Description:
4P
Inrush Power In W:
5.4-5.4 W 20°C)
Insulation Resistance:
> 10 MOhm for Signaling circuit
Contactor Application:
resistive load
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Product Or Component Type:
contactor
Mercury Free:
Yes
Mechanical Durability:
30 Mcycles
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Signaling Circuit Frequency:
25...400 Hz
Operating Time:
63±15 % ms closing || 20±20 % ms opening
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Range Of Product:
TeSys Deca
Flame Retardance:
V1 conforming to UL 94
Standards:
CSA C22.2 No 60947-4-1 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Power Dissipation Per Pole:
1.56 W AC-1
$138.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 1.16 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose