Schneider Electric

Schneider Electric LC1D098BL IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D098BL
MPN:
LC1D098BL
Condition:
New
Minimum Switching Voltage:
17 V for Signaling circuit
Poles Description:
4P
Fire Resistance:
850°C IEC 60695-2-1
Device Short Name:
LC1D
Weight:
0.525 kg
Country of Origin:
United States
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Auxiliary Contact Composition:
1 NO + 1 NC
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Eu Rohs Directive:
Compliant with Exemptions
Signaling Circuit Frequency:
25...400 Hz
Power Dissipation Per Pole:
1.56 W AC-1
Control Circuit Type:
DC low consumption
Compatibility Code:
LC1D
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Protective Treatment:
THIEC 60068-2-30
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 250 V DC
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame Retardance:
V1 conforming to UL 94
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Standards:
CSA C22.2 No 60947-4-1 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Contactor Application:
resistive load
Net Weight:
0.525 kg
Circularity Profile:
ENVEOLI1102030EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
Overvoltage Category:
III
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Range Of Product:
TeSys Deca
Time Constant:
40 ms
Inrush Power In W:
2.4-2.4 W 20°C)
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Width:
45 mm
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Environmental Disclosure:
ENVPEP110230EN
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Minimum Switching Current:
5 mA for Signaling circuit
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Product Certifications:
UL || CCC || CSA || UKCA || EAC || CB || EU-RO-MR by DNV-GL
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Pole Contact Composition:
2 NO + 2 NC
$165.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 1.16 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose