Schneider Electric

Schneider Electric LC1D098U7 IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 240VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D098U7
MPN:
LC1D098U7
Condition:
New
Mechanical Durability:
15 Mcycles
Circularity Profile:
ENVEOLI1501004
Control Circuit Type:
AC 50/60 Hz
Net Weight:
0.365 kg
Sustainable Offer Status:
Green Premium product
Device Short Name:
LC1D
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contact Composition:
1 NO + 1 NC
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Pole Contact Composition:
2 NO + 2 NC
Coil Technology:
without built-in suppressor module
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Mounting Support:
plate || rail
Country of Origin:
United States
Flame Retardance:
V1 conforming to UL 94
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 250 V DC
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Eu Rohs Directive:
Compliant
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
Toxic Heavy Metal Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Operating Altitude:
0...9842.52 ft (0...3000 m)
Signaling Circuit Frequency:
25...400 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Mercury Free:
Yes
Product Or Component Type:
contactor
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Overvoltage Category:
III
Range Of Product:
TeSys Deca
Insulation Resistance:
> 10 MOhm for Signaling circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Width:
45 mm
Standards:
CSA C22.2 No 60947-4-1 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Height:
85 mm
Fire Resistance:
850°C IEC 60695-2-1
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Minimum Switching Current:
5 mA for Signaling circuit
Product Certifications:
UL || CCC || CSA || UKCA || EAC || CB || EU-RO-MR by DNV-GL || LROS (Lloyds register of shipping)
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Compatibility Code:
LC1D
Depth:
92 mm
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
$130.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.