Schneider Electric LC1D09EHE IEC contactor, TeSys Deca Green, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130 VAC/VDC coil, open
Schneider Electric
$41.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.81 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Pollution Degree:
- 3
- Compatibility Code:
- LC1D
- Circularity Profile:
- ENVEOLI1609001EN
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Weight:
- 0.368 kg
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Connections - Terminals:
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Protective Cover:
- with
- Net Weight:
- 0.368 kg
- Range:
- TeSys || TeSys Deca
- [Icw] Rated Short-Time Withstand Current:
- 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1
- Halogen Content Performance:
- Halogen free plastic parts & cables product
- Operating Time:
- 45...55 ms closing || 20...90 ms opening
- Overvoltage Category:
- III
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Pole Contact Composition:
- 3 NO
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC-1 for power circuit || 9 A (at <60°C) at <= 440 V AC-3e for power circuit
- Power Dissipation Per Pole:
- 1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
- Warranty:
- 18 months
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
- Inrush Power In W:
- 24-24 W 20°C)
- Poles Description:
- 3P
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Heat Dissipation:
- 0.8-0.8 W at 50/60 Hz
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Signaling Circuit Frequency:
- 25...400 Hz
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Depth:
- 86 mm
- Coil Technology:
- built-in bidirectional peak limiting
- Hold-In Power Consumption In Va:
- 1.3-1.3 VA 50/60 Hz (at 20°C)
- Inrush Power In Va:
- 25-25 VA 50/60 Hz (at 20°C)
- Flame Retardance:
- V1 conforming to UL 94
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mercury Free:
- Yes
- Product Or Component Type:
- contactor