[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Ip Degree Of Protection:
IP20 front face IEC 60529
Depth:
95 mm
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Fire Resistance:
850°C IEC 60695-2-1
Width:
45 mm
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
Country of Origin:
Indonesia
Minimum Switching Current:
5 mA for Signaling circuit
Compatibility Code:
LC1D
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Device Short Name:
LC1D
Weight:
0.48 kg
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Time Constant:
40 ms
Power Dissipation Per Pole:
1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Inrush Power In W:
2.4-2.4 W 20°C)
Maximum Operating Rate:
3600 cyc/h 60°C
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pollution Degree:
3
Poles Description:
3P
Environmental Disclosure:
ENVPEP110230EN
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Minimum Switching Voltage:
17 V for Signaling circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pole Contact Composition:
3 NO
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Maximum Horse Power Rating:
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phas
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Height:
77 mm
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
Warranty:
18 months
Operating Altitude:
0...9842.52 ft (0...3000 m)
Protective Treatment:
THIEC 60068-2-30
Electrical Durability:
0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V || 2 Mcycles 9 A AC-3e <= 440 V
Pvc Free:
Yes
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
$112.80

Description

TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a low consumption 48V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).