Schneider Electric

Schneider Electric LC1D09FC7 IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 127VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D09FC7
MPN:
LC1D09FC7
Condition:
New
[Uc] Control Circuit Voltage:
127 V AC 50/60 Hz
Protective Treatment:
THIEC 60068-2-30
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
77 mm
Operating Altitude:
0...9842.52 ft (0...3000 m)
Minimum Switching Voltage:
17 V for Signaling circuit
Coil Technology:
without built-in suppressor module
Signaling Circuit Frequency:
25...400 Hz
Circularity Profile:
ENVEOLI1501004
Maximum Horse Power Rating:
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phas
Toxic Heavy Metal Free:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Product Certifications:
UL || CSA || LROS (Lloyds register of shipping) || RINA || GOST || DNV || BV || GL || CCC || UKCA
Pvc Free:
Yes
Protective Cover:
with
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Device Short Name:
LC1D
Depth:
86 mm
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Flame Retardance:
V1 conforming to UL 94
Mercury Free:
Yes
Power Dissipation Per Pole:
1.56 W AC-1 || 0.2 W AC-3 || 0.2 W AC-3e
Mounting Support:
plate || rail
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Auxiliary Contact Composition:
1 NO + 1 NC
Minimum Switching Current:
5 mA for Signaling circuit
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Maximum Operating Rate:
3600 cyc/h 60°C
Weight:
0.32 kg
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Contactor Application:
resistive load || motor control
Environmental Disclosure:
ENVPEP1501004
Net Weight:
0.32 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant
Warranty:
18 months
Insulation Resistance:
> 10 MOhm for Signaling circuit
Pole Contact Composition:
3 NO
Poles Description:
3P
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit
$112.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 127 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose