Schneider Electric LC1D09KUE IEC contactor, TeSys Deca Green, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil, open
Schneider Electric
$36.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.81 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Overvoltage Category:
- III
- Product Or Component Type:
- contactor
- Fire Resistance:
- 850°C IEC 60695-2-1
- Maximum Horse Power Rating:
- 0.33 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp
- Country of Origin:
- United States
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Environmental Disclosure:
- ENVPEP1609001EN
- Range:
- TeSys || TeSys Deca
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Poles Description:
- 3P
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Coil Technology:
- built-in bidirectional peak limiting
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
- Inrush Power In Va:
- 25-25 VA 50/60 Hz (at 20°C)
- Contactor Application:
- motor control || resistive load
- Mechanical Durability:
- 15 Mcycles
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC-3 for power circuit || 25 A (at <60°C) at <= 440 V AC-1 for power circuit || 9 A (at <60°C) at <= 440 V AC-3e for power circuit
- Hold-In Power Consumption In W:
- 1.1-1.1 W 20°C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- [Uc] Control Circuit Voltage:
- 100...250 V AC 50/60 Hz || 100...250 V DC
- Compatibility Code:
- LC1D
- Protective Cover:
- with
- Mercury Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Motor Power Kw:
- 2.2 kW at 220...230 V AC 50 Hz (AC-3) || 4 kW at 380...400 V AC 50 Hz (AC-3) || 4 kW at 415 V AC 50 Hz (AC-3) || 4 kW at 440 V AC 50 Hz (AC-3) || 5.5 kW at 500 V AC 50 Hz (AC-3) || 5.5 kW at 660...690 V AC 50 Hz (AC-3) || 2.2 kW at 220...230 V AC 50
- Electrical Durability:
- 2.4 Mcycles 8 A AC-3 <= 440 V || 0.6 Mcycles 25 A AC-1 <= 440 V || 2.4 Mcycles 8 A AC-3e <= 440 V
- Pollution Degree:
- 3
- Sustainable Offer Status:
- Green Premium product
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Device Short Name:
- LC1D
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Pole Contact Composition:
- 3 NO
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Operating Time:
- 45...55 ms closing || 20...90 ms opening
- Hold-In Power Consumption In Va:
- 1.6-1.6 VA 50/60 Hz (at 20°C)
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Halogen Content Performance:
- Halogen free plastic parts & cables product
- Signaling Circuit Frequency:
- 25...400 Hz
- Mounting Support:
- rail || plate