TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 60 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Control Circuit Type:
- DC standard
- Motor Power Kw:
- 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) || 4 kW at 380...400 V AC 50/60 Hz (AC-3) || 4 kW at 415...440 V AC 50/60 Hz (AC-3) || 5.5 kW at 500 V AC 50/60 Hz (AC-3) || 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 2.2 kW at 400 V AC 50/60 Hz (AC-4) || 2.
- Mechanical Durability:
- 30 Mcycles
- Net Weight:
- 0.48 kg
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Utilisation Category:
- AC-4 || AC-3 || AC-1 || AC-3e
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Electrical Durability:
- 0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V || 2 Mcycles 9 A AC-3e <= 440 V
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Pollution Degree:
- 3
- Operating Time:
- 63±15 % ms closing || 20±20 % ms opening
- Range Of Product:
- TeSys Deca
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- [Ith] Conventional Free Air Thermal Current:
- 25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Device Short Name:
- LC1D
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Pole Contact Composition:
- 3 NO
- Time Constant:
- 28 ms
- Weight:
- 0.48 kg
- Environmental Disclosure:
- ENVPEP110230EN
- Contactor Application:
- motor control || resistive load
- Circularity Profile:
- ENVEOLI1102030EN
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Compatibility Code:
- LC1D
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Poles Description:
- 3P
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Uc] Control Circuit Voltage:
- 60 V DC
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Hold-In Power Consumption In W:
- 5.4-5.4 W 20°C
- Sustainable Offer Status:
- Green Premium product
- Depth:
- 95 mm
- Signaling Circuit Frequency:
- 25...400 Hz
- Tightening Torque:
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- [Icw] Rated Short-Time Withstand Current:
- 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Mercury Free:
- Yes
- Eu Rohs Directive:
- Compliant with Exemptions
- Mounting Support:
- plate || rail
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Flame Retardance:
- V1 conforming to UL 94