Schneider Electric LC1D115004MD IEC contactor, TeSys Deca, nonreversing, 200A resistive, 4 pole, 4 NO, 220VDC coil, open style
Schneider Electric
$673.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 200A resistive load rating. Contactor is supplied with a 220 VDC coil with integral suppression device. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 6.10 inches wide and 4.53 inches deep. It weighs 6.31 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Operating Time:
- 20...35 ms closing || 40...75 ms opening
- Tightening Torque:
- control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Electrical Durability:
- 0.8 Mcycles 200 A AC-1 <= 440 V
- Inrush Power In W:
- 270-365 W 20°C)
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Protective Cover:
- with
- Country of Origin:
- Czechia
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Rated Breaking Capacity:
- 1100 A at 440 V for power circuit conforming to IEC 60947
- Overvoltage Category:
- III
- [Uc] Control Circuit Voltage:
- 220 V DC
- Pollution Degree:
- 3
- Product Or Component Type:
- contactor
- [Ie] Rated Operational Current:
- 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Power Dissipation Per Pole:
- 24 W AC-1
- Control Circuit Voltage Limits:
- 0.75...1.2 Uc -40-55°C operational DC || 0.15...0.4 Uc -40-70°C drop-out DC || 1...1.2 Uc 55-70°C operational DC
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
- [Ith] Conventional Free Air Thermal Current:
- 200 A (at 60°C) for power circuit
- Circularity Profile:
- ENVEOLI100405EN
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
- Associated Fuse Rating:
- 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit
- Range:
- TeSys
- Sustainable Offer Status:
- Green Premium product
- Fire Resistance:
- 850°C IEC 60695-2-1
- Pvc Free:
- Yes
- Weight:
- 2.86 kg
- Depth:
- 132 mm
- Warranty:
- 18 months
- Net Weight:
- 2.86 kg
- Control Circuit Type:
- DC standard
- Irms Rated Making Capacity:
- 1260 A at 440 V for power circuit conforming to IEC 60947
- Mounting Support:
- rail || plate
- Height:
- 158 mm
- Rohs Exemption Information:
- Yes
- Environmental Disclosure:
- ENVPEP060301EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 460 V DC
- Mercury Free:
- Yes
- Safety Reliability Level:
- B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
- Time Constant:
- 25 ms
- Maximum Operating Rate:
- 1200 cyc/h 60°C
- Eu Rohs Directive:
- Compliant with Exemptions
- Protective Treatment:
- THIEC 60068-2-30
- [Icw] Rated Short-Time Withstand Current:
- 250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit
- Compatibility Code:
- LC1D